Skip to content
+90 549 541 17 11 +90 549 541 17 53
Teknik Destek / Technical Support Satış Sonrası Teknik Destek / After-Sales Technical Support +90 549 541 17 07
info: info@planersogutma.com Sales: satis@planersogutma.com Service: servis@planersogutma.com
PRD-V Serisi
Dry Coolers

PRD-V Serisi

Model PRD-V

The PRD-V Serisi is a range of V-type dry coolers covering 138 kW – 939 kW. Axial-fan, low-noise design with PLANER-built finned-tube heat exchangers for closed-circuit water/glycol cooling duties. Dimensions and connection sizes are given per model in the table.

Cooling capacity
138 kW – 939 kW
Technical data

Select a model

Performance figures, dimensions and the datasheet for every model in the series.

Technical specifications — PRD V 80 102 A 5"
Capacity (Water) kW 138,5
Air Flow m³/h 41.062
Number of Fans Pcs. 2
Fan Power kW 4,0
Fan Current A 8
Fan Sound Level (10 m) dBA 50
Tube Volume L 47,9
L mm 2300
W mm 1570
H mm 1755
Water Inlet Connection " 2"
Water Outlet Connection " 2"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 103 A 5"
Capacity (Water) kW 205,0
Air Flow m³/h 61.640
Number of Fans Pcs. 3
Fan Power kW 6,0
Fan Current A 12
Fan Sound Level (10 m) dBA 52
Tube Volume L 72,9
L mm 3385
W mm 1570
H mm 1755
Water Inlet Connection " 2 ½"
Water Outlet Connection " 2 ½"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 104 A 5"
Capacity (Water) kW 277,7
Air Flow m³/h 82.250
Number of Fans Pcs. 4
Fan Power kW 8,0
Fan Current A 16
Fan Sound Level (10 m) dBA 53
Tube Volume L 98
L mm 4470
W mm 1570
H mm 1755
Water Inlet Connection " 2 ½"
Water Outlet Connection " 2 ½"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 105 A 5"
Capacity (Water) kW 338,1
Air Flow m³/h 102.812
Number of Fans Pcs. 5
Fan Power kW 10,0
Fan Current A 20
Fan Sound Level (10 m) dBA 54
Tube Volume L 123
L mm 5555
W mm 1570
H mm 1755
Water Inlet Connection " 3"
Water Outlet Connection " 3"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 106 A 5"
Capacity (Water) kW 410,6
Air Flow m³/h 123.375
Number of Fans Pcs. 6
Fan Power kW 12,0
Fan Current A 24
Fan Sound Level (10 m) dBA 55
Tube Volume L 157,4
L mm 6640
W mm 1570
H mm 1755
Water Inlet Connection " 4"
Water Outlet Connection " 4"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 107 A 5"
Capacity (Water) kW 483,5
Air Flow m³/h 144.046
Number of Fans Pcs. 7
Fan Power kW 14,0
Fan Current A 28
Fan Sound Level (10 m) dBA 56
Tube Volume L 198,9
L mm 7725
W mm 1570
H mm 1755
Water Inlet Connection " 5"
Water Outlet Connection " 5"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 202 A 5"
Capacity (Water) kW 268,9
Air Flow m³/h 121.031
Number of Fans Pcs. 4
Fan Power kW 8,0
Fan Current A 16
Fan Sound Level (10 m) dBA 53
Tube Volume L 95,8
L mm 2530
W mm 2400
H mm 2445
Water Inlet Connection " 2x2"
Water Outlet Connection " 2x2"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 203 A 5"
Capacity (Water) kW 398,5
Air Flow m³/h 116.718
Number of Fans Pcs. 6
Fan Power kW 12,0
Fan Current A 24
Fan Sound Level (10 m) dBA 55
Tube Volume L 145,8
L mm 3730
W mm 2400
H mm 2445
Water Inlet Connection " 2x2 ½"
Water Outlet Connection " 2 ½"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 204 A 5"
Capacity (Water) kW 539,2
Air Flow m³/h 161.500
Number of Fans Pcs. 8
Fan Power kW 16,0
Fan Current A 32
Fan Sound Level (10 m) dBA 56
Tube Volume L 196
L mm 4930
W mm 2400
H mm 2445
Water Inlet Connection " 2x2 ½"
Water Outlet Connection " 2x2 ½"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 205 A 5"
Capacity (Water) kW 657,8
Air Flow m³/h 201.875
Number of Fans Pcs. 10
Fan Power kW 20,0
Fan Current A 40
Fan Sound Level (10 m) dBA 57
Tube Volume L 246
L mm 6130
W mm 2400
H mm 2445
Water Inlet Connection " 2x3"
Water Outlet Connection " 2x3"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 206 A 5"
Capacity (Water) kW 798,2
Air Flow m³/h 242.250
Number of Fans Pcs. 12
Fan Power kW 24,0
Fan Current A 48
Fan Sound Level (10 m) dBA 58
Tube Volume L 314,8
L mm 7330
W mm 2400
H mm 2445
Water Inlet Connection " 2x4"
Water Outlet Connection " 2x4"

Specifications are indicative. Final performance is confirmed at design selection.

Technical specifications — PRD V 80 207 A 5"
Capacity (Water) kW 938,6
Air Flow m³/h 282.625
Number of Fans Pcs. 14
Fan Power kW 28,0
Fan Current A 56
Fan Sound Level (10 m) dBA 58
Tube Volume L 397,8
L mm 8530
W mm 2400
H mm 2445
Water Inlet Connection " 2x5"
Water Outlet Connection " 2x5"

Specifications are indicative. Final performance is confirmed at design selection.

Key features

Technical specifications

Capacity (water) 138 kW – 939 kW
Type V-type dry cooler
Fan Axial

Specifications are indicative. Final performance is confirmed at design selection.

Related

You may also consider

PD-D Serisi
Dry Coolers

PD-D Serisi

Vertical-type dry cooler covering 146 kW – 867 kW.

146 kW – 867 kW
PD-Y Serisi
Dry Coolers

PD-Y Serisi

Horizontal-type dry cooler covering 146 kW – 867 kW.

146 kW – 867 kW
PD-V Serisi
Dry Coolers

PD-V Serisi

V-type dry cooler covering 149 kW – 890 kW.

149 kW – 890 kW

Need help sizing the PRD-V Serisi?

Send us your cooling load, fluid temperatures and ambient conditions — we'll confirm the right configuration for your process.

We use cookies to measure site traffic and improve our marketing. Analytics and advertising cookies are only set if you accept. Privacy Policy