PD-Y Serisi
Model PD-Y
The PD-Y Serisi is a range of horizontal-type dry coolers covering 146 kW – 867 kW. Axial-fan, low-noise design with PLANER-built finned-tube heat exchangers for closed-circuit water/glycol cooling duties. Dimensions and connection sizes are given per model in the table.
- Cooling capacity
- 146 kW – 867 kW
Select a model
Performance figures, dimensions and the datasheet for every model in the series.
| Capacity (Water) | kW | 146,99 |
|---|---|---|
| Air Flow | m³/h | 41375 |
| Number of Fans | Pcs. | 2 |
| Fan Power | kW | 4 |
| Fan Current | A | 8 |
| Fan Sound Level (10 m) | dBA | 50 |
| Tube Volume | L | 54,3 |
| L | mm | 2260 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2" |
| Water Outlet Connection | " | 2" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 183,56 |
|---|---|---|
| Air Flow | m³/h | 57422 |
| Number of Fans | Pcs. | 3 |
| Fan Power | kW | 6 |
| Fan Current | A | 12 |
| Fan Sound Level (10 m) | dBA | 52 |
| Tube Volume | L | 82,1 |
| L | mm | 3890 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2 ½" |
| Water Outlet Connection | " | 2 ½" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 248,52 |
|---|---|---|
| Air Flow | m³/h | 76625 |
| Number of Fans | Pcs. | 4 |
| Fan Power | kW | 8 |
| Fan Current | A | 16 |
| Fan Sound Level (10 m) | dBA | 53 |
| Tube Volume | L | 109,9 |
| L | mm | 5120 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2 ½" |
| Water Outlet Connection | " | 2 ½" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 303,41 |
|---|---|---|
| Air Flow | m³/h | 95859 |
| Number of Fans | Pcs. | 5 |
| Fan Power | kW | 10 |
| Fan Current | A | 20 |
| Fan Sound Level (10 m) | dBA | 54 |
| Tube Volume | L | 137,8 |
| L | mm | 6350 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 3" |
| Water Outlet Connection | " | 3" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 368,41 |
|---|---|---|
| Air Flow | m³/h | 115125 |
| Number of Fans | Pcs. | 6 |
| Fan Power | kW | 12 |
| Fan Current | A | 24 |
| Fan Sound Level (10 m) | dBA | 55 |
| Tube Volume | L | 179,1 |
| L | mm | 7620 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 4" |
| Water Outlet Connection | " | 4" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 433,29 |
|---|---|---|
| Air Flow | m³/h | 134312 |
| Number of Fans | Pcs. | 7 |
| Fan Power | kW | 14 |
| Fan Current | A | 28 |
| Fan Sound Level (10 m) | dBA | 56 |
| Tube Volume | L | 227,4 |
| L | mm | 8890 |
| W | mm | 1835 |
| H | mm | 1130 |
| Water Inlet Connection | " | 5" |
| Water Outlet Connection | " | 5" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 293,98 |
|---|---|---|
| Air Flow | m³/h | 82750 |
| Number of Fans | Pcs. | 4 |
| Fan Power | kW | 8 |
| Fan Current | A | 16 |
| Fan Sound Level (10 m) | dBA | 53 |
| Tube Volume | L | 108,6 |
| L | mm | 2260 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x2" |
| Water Outlet Connection | " | 2x2" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 367,12 |
|---|---|---|
| Air Flow | m³/h | 114844 |
| Number of Fans | Pcs. | 6 |
| Fan Power | kW | 12 |
| Fan Current | A | 24 |
| Fan Sound Level (10 m) | dBA | 55 |
| Tube Volume | L | 164,2 |
| L | mm | 3890 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x2 ½" |
| Water Outlet Connection | " | 2 ½" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 497,04 |
|---|---|---|
| Air Flow | m³/h | 153250 |
| Number of Fans | Pcs. | 8 |
| Fan Power | kW | 16 |
| Fan Current | A | 32 |
| Fan Sound Level (10 m) | dBA | 56 |
| Tube Volume | L | 219,8 |
| L | mm | 5120 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x2 ½" |
| Water Outlet Connection | " | 2x2 ½" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 606,82 |
|---|---|---|
| Air Flow | m³/h | 191718 |
| Number of Fans | Pcs. | 10 |
| Fan Power | kW | 20 |
| Fan Current | A | 40 |
| Fan Sound Level (10 m) | dBA | 57 |
| Tube Volume | L | 275,6 |
| L | mm | 6350 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x3" |
| Water Outlet Connection | " | 2x3" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 736,82 |
|---|---|---|
| Air Flow | m³/h | 230250 |
| Number of Fans | Pcs. | 12 |
| Fan Power | kW | 24 |
| Fan Current | A | 48 |
| Fan Sound Level (10 m) | dBA | 58 |
| Tube Volume | L | 358,2 |
| L | mm | 7620 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x4" |
| Water Outlet Connection | " | 2x4" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
| Capacity (Water) | kW | 866,58 |
|---|---|---|
| Air Flow | m³/h | 268624 |
| Number of Fans | Pcs. | 14 |
| Fan Power | kW | 28 |
| Fan Current | A | 56 |
| Fan Sound Level (10 m) | dBA | 58 |
| Tube Volume | L | 454,8 |
| L | mm | 8890 |
| W | mm | 3715 |
| H | mm | 1130 |
| Water Inlet Connection | " | 2x5" |
| Water Outlet Connection | " | 2x5" |
Specifications are indicative. Final performance is confirmed at design selection.
Technical drawing
Documents
Key features
Technical specifications
| Capacity (water) | 146 kW – 867 kW |
|---|---|
| Type | Horizontal-type dry cooler |
| Fan | Axial |
Specifications are indicative. Final performance is confirmed at design selection.
You may also consider
Need help sizing the PD-Y Serisi?
Send us your cooling load, fluid temperatures and ambient conditions — we'll confirm the right configuration for your process.