Skip to content
YHA-V Serisi
Air Cooled Chillers

YHA-V Serisi

Model YHA-V

The YHA-V Series comprises air-cooled water chillers with screw compressors. Stepless capacity control and low-vibration running hold a steady process temperature in high-capacity plants. Uses environmentally friendly R 407 C refrigerant.

Cooling capacity
156,4 – 1.270,3 kW
Refrigerant
R 407 C
Technical data

Select a model

Performance figures, dimensions and the datasheet for every model in the series.

Technical specifications — P 501 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 3 x Ø800
Fan sound pressure level (10 m) dBA 47
Required evaporator water flow m³/h 27
L mm 3750
W mm 1260
H mm 2465
Water inlet connection " DN 80
Water outlet connection " DN 80
Weight kg 1500
Cooling capacity kW 156,4
Cooling capacity kcal/h 134.553
Total compressor power kW 34,4
Total power input kW 40,3
Cooling capacity kW 147,5
Cooling capacity kcal/h 126.912
Total compressor power kW 37,4
Total power input kW 43,3
Cooling capacity kW 104,3
Cooling capacity kcal/h 89.768
Total compressor power kW 38
Total power input kW 43,8
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 501 YHA-V — Technical drawing
Technical specifications — P 601 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 3 x Ø800
Fan sound pressure level (10 m) dBA 48
Required evaporator water flow m³/h 33
L mm 3750
W mm 1260
H mm 2465
Water inlet connection " DN 80
Water outlet connection " DN 80
Weight kg 1600
Cooling capacity kW 192,8
Cooling capacity kcal/h 165.889
Total compressor power kW 41,4
Total power input kW 47,3
Cooling capacity kW 181,9
Cooling capacity kcal/h 156.493
Total compressor power kW 44,7
Total power input kW 50,5
Cooling capacity kW 128,6
Cooling capacity kcal/h 110.633
Total compressor power kW 45,4
Total power input kW 51,2
Energy efficiency ratio (EER) 2,5

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 601 YHA-V — Technical drawing
Technical specifications — P 701 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 4 x Ø800
Fan sound pressure level (10 m) dBA 48
Required evaporator water flow m³/h 38
L mm 2900
W mm 2250
H mm 2200
Water inlet connection " DN 100
Water outlet connection " DN 100
Weight kg 1700
Cooling capacity kW 220,5
Cooling capacity kcal/h 189.688
Total compressor power kW 45,2
Total power input kW 52,9
Cooling capacity kW 205,7
Cooling capacity kcal/h 177.023
Total compressor power kW 49,8
Total power input kW 57,6
Cooling capacity kW 138,6
Cooling capacity kcal/h 119.246
Total compressor power kW 53,3
Total power input kW 61
Energy efficiency ratio (EER) 2,3

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 701 YHA-V — Technical drawing
Technical specifications — P 801 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 3 x Ø800
Fan sound pressure level (10 m) dBA 53
Required evaporator water flow m³/h 44
L mm 3280
W mm 2250
H mm 2530
Water inlet connection " DN 100
Water outlet connection " DN 100
Weight kg 1900
Cooling capacity kW 255,2
Cooling capacity kcal/h 219.734
Total compressor power kW 51,2
Total power input kW 59
Cooling capacity kW 238,4
Cooling capacity kcal/h 205.107
Total compressor power kW 56
Total power input kW 63,8
Cooling capacity kW 159,7
Cooling capacity kcal/h 137.435
Total compressor power kW 59,9
Total power input kW 67,7
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 801 YHA-V — Technical drawing
Technical specifications — P 1001 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 6 x Ø800
Fan sound pressure level (10 m) dBA 50
Required evaporator water flow m³/h 58
L mm 4325
W mm 2250
H mm 2500
Water inlet connection " DN 125
Water outlet connection " DN 125
Weight kg 2500
Cooling capacity kW 335,9
Cooling capacity kcal/h 288.981
Total compressor power kW 64,5
Total power input kW 76,2
Cooling capacity kW 313,8
Cooling capacity kcal/h 270.000
Total compressor power kW 70,8
Total power input kW 82,5
Cooling capacity kW 210
Cooling capacity kcal/h 180.688
Total compressor power kW 76,3
Total power input kW 87,9
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1001 YHA-V — Technical drawing
Technical specifications — P 1201 YHA-V
Number of compressors pcs 1
Refrigeration circuits pcs 1
Capacity control % %50-%100
Fan quantity / diameter pcs / mm 8 x Ø800
Fan sound pressure level (10 m) dBA 55
Required evaporator water flow m³/h 68
L mm 5525
W mm 2250
H mm 2550
Water inlet connection " DN 125
Water outlet connection " DN 125
Weight kg 2800
Cooling capacity kW 395,4
Cooling capacity kcal/h 340.185
Total compressor power kW 75,9
Total power input kW 91,4
Cooling capacity kW 371
Cooling capacity kcal/h 319.225
Total compressor power kW 83,4
Total power input kW 98,9
Cooling capacity kW 250,32
Cooling capacity kcal/h 215.380
Total compressor power kW 88,9
Total power input kW 104,5
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1201 YHA-V — Technical drawing
Technical specifications — P 502 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 6 x Ø800
Fan sound pressure level (10 m) dBA 50
Required evaporator water flow m³/h 54
L mm 4325
W mm 2250
H mm 2480
Water inlet connection " DN 125
Water outlet connection " DN 125
Weight kg 2700
Cooling capacity kW 312,8
Cooling capacity kcal/h 269.105
Total compressor power kW 68,9
Total power input kW 80,5
Cooling capacity kW 295
Cooling capacity kcal/h 253.824
Total compressor power kW 74,9
Total power input kW 86,5
Cooling capacity kW 208,7
Cooling capacity kcal/h 179.535
Total compressor power kW 76
Total power input kW 87,7
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 502 YHA-V — Technical drawing
Technical specifications — P 602 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 8 x Ø800
Fan sound pressure level (10 m) dBA 51
Required evaporator water flow m³/h 66
L mm 5525
W mm 2250
H mm 2550
Water inlet connection " DN 125
Water outlet connection " DN 125
Weight kg 3200
Cooling capacity kW 385,6
Cooling capacity kcal/h 331.778
Total compressor power kW 82,9
Total power input kW 98,4
Cooling capacity kW 363,8
Cooling capacity kcal/h 312.987
Total compressor power kW 89,4
Total power input kW 105
Cooling capacity kW 257,2
Cooling capacity kcal/h 221.266
Total compressor power kW 90,8
Total power input kW 106,4
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 602 YHA-V — Technical drawing
Technical specifications — P 702 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 8 x Ø800
Fan sound pressure level (10 m) dBA 51
Required evaporator water flow m³/h 76
L mm 5525
W mm 2250
H mm 2550
Water inlet connection " DN 125
Water outlet connection " DN 125
Weight kg 3400
Cooling capacity kW 440,9
Cooling capacity kcal/h 379.377
Total compressor power kW 90,3
Total power input kW 105,8
Cooling capacity kW 411,5
Cooling capacity kcal/h 354.046
Total compressor power kW 99,6
Total power input kW 115,2
Cooling capacity kW 277,2
Cooling capacity kcal/h 238.491
Total compressor power kW 106,5
Total power input kW 122
Energy efficiency ratio (EER) 2,3

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 702 YHA-V — Technical drawing
Technical specifications — P 802 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 8 x Ø800
Fan sound pressure level (10 m) dBA 56
Required evaporator water flow m³/h 88
L mm 5525
W mm 2250
H mm 2550
Water inlet connection " DN 150
Water outlet connection " DN 150
Weight kg 3600
Cooling capacity kW 510,8
Cooling capacity kcal/h 439.468
Total compressor power kW 102,4
Total power input kW 118
Cooling capacity kW 476,8
Cooling capacity kcal/h 410.214
Total compressor power kW 112
Total power input kW 127,5
Cooling capacity kW 319,5
Cooling capacity kcal/h 274.870
Total compressor power kW 119,8
Total power input kW 135,3
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 802 YHA-V — Technical drawing
Technical specifications — P 1002 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 10 x Ø800
Fan sound pressure level (10 m) dBA 53
Required evaporator water flow m³/h 116
L mm 6725
W mm 2250
H mm 2550
Water inlet connection " DN 150
Water outlet connection " DN 150
Weight kg 4400
Cooling capacity kW 671,7
Cooling capacity kcal/h 577.962
Total compressor power kW 129
Total power input kW 148,4
Cooling capacity kW 627,6
Cooling capacity kcal/h 540.000
Total compressor power kW 141,7
Total power input kW 161,1
Cooling capacity kW 420
Cooling capacity kcal/h 361.377
Total compressor power kW 152,5
Total power input kW 171,9
Energy efficiency ratio (EER) 2,4

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1002 YHA-V — Technical drawing
Technical specifications — P 1202 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 12 x Ø800
Fan sound pressure level (10 m) dBA 58
Required evaporator water flow m³/h 136
L mm 7925
W mm 2250
H mm 2550
Water inlet connection " DN 150
Water outlet connection " DN 150
Weight kg 5300
Cooling capacity kW 790,7
Cooling capacity kcal/h 680.369
Total compressor power kW 151,8
Total power input kW 175,1
Cooling capacity kW 742
Cooling capacity kcal/h 638.449
Total compressor power kW 166,7
Total power input kW 190
Cooling capacity kW 500,6
Cooling capacity kcal/h 430.761
Total compressor power kW 177,9
Total power input kW 201,2
Energy efficiency ratio (EER) 2,5

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1202 YHA-V — Technical drawing
Technical specifications — P 1402 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 14 x Ø800
Fan sound pressure level (10 m) dBA 55
Required evaporator water flow m³/h 173
L mm 9125
W mm 2250
H mm 2550
Water inlet connection " DN 150
Water outlet connection " DN 150
Weight kg 5800
Cooling capacity kW 1004,8
Cooling capacity kcal/h 864.551
Total compressor power kW 193,6
Total power input kW 220,8
Cooling capacity kW 935,4
Cooling capacity kcal/h 804.820
Total compressor power kW 212,4
Total power input kW 239,6
Cooling capacity kW 637,1
Cooling capacity kcal/h 548.140
Total compressor power kW 220,6
Total power input kW 247,8
Energy efficiency ratio (EER) 2,6

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1402 YHA-V — Technical drawing
Technical specifications — P 1602 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 16 x Ø800
Fan sound pressure level (10 m) dBA 55
Required evaporator water flow m³/h 188
L mm 10325
W mm 2250
H mm 2550
Water inlet connection " DN 200
Water outlet connection " DN 200
Weight kg 6300
Cooling capacity kW 1091,4
Cooling capacity kcal/h 939.063
Total compressor power kW 211,8
Total power input kW 242,8
Cooling capacity kW 1018,5
Cooling capacity kcal/h 876.304
Total compressor power kW 233,2
Total power input kW 264,2
Cooling capacity kW 694,5
Cooling capacity kcal/h 597.597
Total compressor power kW 241,2
Total power input kW 272,2
Energy efficiency ratio (EER) 2,6

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1602 YHA-V — Technical drawing
Technical specifications — P 1802 YHA-V
Number of compressors pcs 2
Refrigeration circuits pcs 2
Capacity control % %25-%50-%75-%100
Fan quantity / diameter pcs / mm 20 x Ø800
Fan sound pressure level (10 m) dBA 60
Required evaporator water flow m³/h 218
L mm 12725
W mm 2250
H mm 2550
Water inlet connection " DN 200
Water outlet connection " DN 200
Weight kg 6500
Cooling capacity kW 1270,3
Cooling capacity kcal/h 1.092.958
Total compressor power kW 241,6
Total power input kW 280,4
Cooling capacity kW 1191,6
Cooling capacity kcal/h 1.025.312
Total compressor power kW 266,2
Total power input kW 305
Cooling capacity kW 803,3
Cooling capacity kcal/h 691.141
Total compressor power kW 283,6
Total power input kW 322,4
Energy efficiency ratio (EER) 2,5

Specifications are indicative. Final performance is confirmed at design selection.

Technical drawing

P 1802 YHA-V — Technical drawing

Key features

Technical specifications

Cooling capacity 156,4 – 1.270,3 kW
Refrigerant R 407 C

Specifications are indicative. Final performance is confirmed at design selection.

Related

You may also consider

HA-S Serisi
Air Cooled Chillers

HA-S Serisi

Air-cooled water chiller with scroll compressors, from 16 to 98 kW.

16 – 98 kW R 407 C
Multicold HA-S Serisi
Air Cooled Chillers

Multicold HA-S Serisi

High-capacity air-cooled water chiller with multiple scroll compressors.

107,2 – 442 kW R 407 C
YHA Serisi
Air Cooled Chillers

YHA Serisi

Air-cooled water chiller with piston compressors.

55,5 – 402,4 kW R 407 C

Need help sizing the YHA-V Serisi?

Send us your cooling load, fluid temperatures and ambient conditions — we'll confirm the right configuration for your process.